June 18, 2020 18:45 by
admin
Electrocoagulation-electroflotation (ECF) technology is a treatment process of applying electrical current to treat and flocculate contaminants without having to add coagulations. Shammas et al. stated that coagulation occurs with the current being applied, capable of removing small particles since direct current applied, setting them into motion. Also electrocoagulation could reduce residue for waste production
[More]
June 15, 2020 16:56 by
admin
Treatment with electrochemical and chemical coagulation process. ... oxygen demand in effluent, it directly affects the soil fertility i.e., plant growth and seed ... pH of treated wastewater were modified with acid and base solution of H2SO4
[More]
June 13, 2020 18:04 by
admin
The system describes the treatment of different wastewater types by EOx method in the last few years. It shows a general insight on minimum, maximum, and optimum values of operating parametersble , pollutant reduction, energy consumption, and operating cost of EOx treatment. By evaluating the previously published studies, it has been concluded that EOx is a remarkable treatment method in terms of organic matter, turbidity, color, phenol, total Kjeldahl nitrogen (TKN), and O&G removal efficiencies.
[More]
June 11, 2020 14:53 by
admin
Mobile Wastewater Treatment Plant based on Electrocoagulation and Electro-Oxidation - Truck Mounted / Mini Van mounted Advanced Effluent Treatment Plant
[More]
June 11, 2020 14:53 by
admin
Mobile Wastewater Treatment Plant based on Electrocoagulation and Electro-Oxidation - Truck Mounted / Mini Van mounted Advanced Effluent Treatment Plant
[More]
June 10, 2020 18:07 by
admin
Electrochemical techniques use one of the cleanest reagents: “the electron.” Thus, since the main reactive used in the oxidation process is green, this becomes sustainable. Oxidation of the organic compounds could occur at the interface of the anode/aqueous solution or in solution via intermediates.
[More]
June 9, 2020 17:24 by
admin
ETP consider how effective the ECF reactor can be, one must consider the following inputs or variableswastewater type, pH, current density, type of metal electrodes (aluminum, steel, iron), number of electrodes, size of electrodes, and configuration of metals.
[More]
June 6, 2020 19:12 by
admin
The most general layout comprises two electrodes, operating as anode and cathode, connected to a power source. When an energy input and sufficient supporting electrolyte are provided to the system, strong oxidizing species are formed, which interact with the contaminants and degrade them
[More]
June 6, 2020 19:12 by
admin
The most general layout comprises two electrodes, operating as anode and cathode, connected to a power source. When an energy input and sufficient supporting electrolyte are provided to the system, strong oxidizing species are formed, which interact with the contaminants and degrade them
[More]
June 4, 2020 19:36 by
admin
Traditional wastewater treatments involve the addition of chemicals or the use of microorganisms to treat polluted water. However, in both processes, there is always a residue known as sludge. The sludge management and final disposal could represent up to 50% of the total wastewater treatment plant cost