Water Sanitizer

NaOCl, HOCl

Tiaano Waste Water Treatment by Electrolytic Method

clock July 8, 2020 18:56 by author admin
Mixing intensity and residence time determine whether the stated goals will be met. To determine mixing intensity define as the average shear intensity (mean velocity gradient) in the rapid-mix tank. The Camp-Stein equation is often used to compute this , however it is an equation which is based on laminar flow -- a case seldom found in rapid-mix or flocculation basins so it’s an “average” approximation. [More]


ELECTROLYTIC PRELIMINARY TEST/ APPRAISAL TEST KIT

clock July 3, 2020 14:41 by author admin
Electrocoagulation-flotation is an alternative method to classic chemical coagulation for many reasons. ECF is capable of reducing the need for chemicals due to the fact that the electrodes provide the coagulant. However, many individuals still use chemical coagulants to attempt to enhance treatment. Traditionally, chemical coagulation involves the use of alum (aluminum sulfate), ferric chloride (FeCl3), or ferrous sulfate (Fe2SO4) which can be very expensive depending on the volume of water treated. When applying the coagulant, the coagulant performs a similar function as the electrodes, neutralizing the charge of the particulates, thereby allow them to agglomerate and settle at the bottom of the tank. In addition, electrocoagulation-flotation is capable of reducing waste production from wastewater treatment and also reduces the time necessary for treatment. [More]


EFFLUENT TREATMENT PLANT & SEWAGE TREATMENT PLANT

clock June 30, 2020 20:46 by author admin
Electrocoagulation-electroflotation (ECF) technology is a treatment process of applying electrical current to treat and flocculate contaminants without having to add coagulations. Shammas et al. stated that coagulation occurs with the current being applied, capable of removing small particles since direct current applied, setting them into motion. Also electrocoagulation could reduce residue for waste production. [More]


Report of Analysis Tiaano’s Chloro-Sanitizer Generator for Generation of Sodium Hypochlorite (5000 ppm)

clock June 30, 2020 11:22 by author admin
Tiaano design, manufacturing and supplying Chloro-Sanitizer Generator for the generation of Sodium hypochlorite as disinfectant. [More]


EFFLUENT TREATMENT PLANT AND SEWAGE TREATMENT PLANT

clock June 29, 2020 20:34 by author admin
Electro coagulation-electro floatation (ECF) technology is a treatment process of applying electrical current to treat and flocculate contaminants without having to add coagulations. It occurs with the current being applied, capable of removing small particles since direct current applied, setting them into motion. Also electro coagulation could reduce residue for waste production. Electro Coagulation Reactor (ECR) consists of electrodes, which is arranged in anode & cathode. Using the principles of electrochemistry, the cathode is oxidized (loses electrons), while the water is reduced (gains electrons), thereby making the wastewater better treated. [More]


Waste Water Treatment by Electrolytic Method

clock June 27, 2020 16:47 by author admin
Electro-oxidation (EO), also known as anodic oxidation, is a technique used for wastewater treatment, mainly for industrial effluents, and is a type of advanced oxidation process (AOP).[1] The most general layout comprises two electrodes, operating as anode and cathode, connected to a power source. When an energy input and sufficient supporting electrolyte are provided to the system, strong oxidizing species are formed, which interact with the contaminants and degrade them. The refractory compounds are thus converted into reaction intermediates and, ultimately, into water and CO2 by complete mineralization [More]


Waste Water Treatment by Electrolytic Method

clock June 27, 2020 16:47 by author admin
Electro-oxidation (EO), also known as anodic oxidation, is a technique used for wastewater treatment, mainly for industrial effluents, and is a type of advanced oxidation process (AOP).[1] The most general layout comprises two electrodes, operating as anode and cathode, connected to a power source. When an energy input and sufficient supporting electrolyte are provided to the system, strong oxidizing species are formed, which interact with the contaminants and degrade them. The refractory compounds are thus converted into reaction intermediates and, ultimately, into water and CO2 by complete mineralization [More]


MMO Coated Titanium Anode & Titanium Cathode for the Application of Chloro-Sanitizer Generator

clock June 26, 2020 12:51 by author admin
Tiaano MMO Coated Titanium Anodes and Titanium Cathodes designed to use in Sodium Hypochlorite Generator / Chloro Sanitizer / Electro Chlorinator. Sodium hypochlorite (NaOCl) is a compound that can be effectively used for water disinfection. It is used on a large scale for surface disinfection, bleaching, odor removal and water disinfection. [More]


Tiaano Waste Water Treatment by Electrolytic Method in Textile Plant

clock June 25, 2020 18:16 by author admin
Electrocoagulation-flotation is an alternative method to classic chemical coagulation for many reasons. ECF is capable of reducing the need for chemicals due to the fact that the electrodes provide the coagulant. However, many individuals still use chemical coagulants to attempt to enhance treatment. Traditionally, chemical coagulation involves the use of alum (aluminum sulfate), ferric chloride (FeCl3), or ferrous sulfate (Fe2SO4) which can be very expensive depending on the volume of water treated. When applying the coagulant, the coagulant performs a similar function as the electrodes, neutralizing the charge of the particulates, thereby allow them to agglomerate and settle at the bottom of the tank. In addition, electrocoagulation-flotation is capable of reducing waste production from wastewater treatment and also reduces the time necessary for treatment. [More]


Report of Analysis Tiaano’s Chloro-Sanitizer Generator for Generation of Sodium Hypochlorite (02 ppm)

clock June 25, 2020 10:34 by author admin
Tiaano design, manufacturing and supplying Chloro-Sanitizer Generator for the generation of Sodium hypochlorite as disinfectant. The below enclosed test report of 02 ppm is self-explanatory. [More]