Water Sanitizer

NaOCl, HOCl

ELECTROLYTIC EFFLUENT TREATMENT PLANT (e-ETP)

clock July 17, 2020 21:18 by author admin
Electrocoagulation / Electroflotation Reactor is compact, eco-friendly, ... Electroflotation Combined Systems for Effective Wastewater Teatment ... Electrocoagulation and Electro-Oxidation based Hybrid Effluent treatment plant / systems .. [More]


APPLICATIONS OF e-ETP & e-STP SYSTEM FOR VARIOUS INDUSTRIES

clock July 15, 2020 19:54 by author admin
wastewater treatment; electrocoagulation; electrooxidation; combined ... or by flotation based on the formation of hydrogen gas at the cathode as. per unit volume of treated wastewater is reduced [More]


ELECTROLYTIC EFFLUENT TREATMENT PLANT (e-ETP)

clock July 13, 2020 19:09 by author admin
Large volumes of waste water with numerous pollutants are discharged. Since these streams of water affect the aquatic eco-system in number of ways such as depleting the dissolved oxygen content or settlement of suspended substances in anaerobic condition, a special attention needs to be paid. Thus a study on different measures which can be adopted to treat the waste water discharged from textile chemical processing industries to protect and safeguard our surroundings from possible pollution problem has been the focus point of many recent investigations. This communication highlights such studies carried out in the area of textile effluent treatment. [More]


Waste Water Treatment by Electrolytic Method

clock July 10, 2020 21:05 by author admin
This category of waste includes those that are persistent, resist treatment, or interfere with the operation of waste treatment facilities. Non-biodegradable organic or inorganic materials are the chief sources of wastes, which contain colour, metals, phenols, certain surfactants, toxic organic compounds, pesticides and phosphates [More]


e-ETP Advanced Oxidation Process in TEXTILE INDUSTRIES

clock July 9, 2020 19:36 by author admin
The final goal of AOPS is the complete degradation of the pollutants present in wastewater, aiming its final mineralization, yielding as final products: carbon dioxide, water and inorganic compounds. These methodologies solve the problem of the final disposal of sludge; because when they are well developed, there is no production of sludge. Obviously, not always is possible the complete mineralization of contaminates. Nevertheless, most of the times, the final products of the destruction of contaminants are harmless compared to the original ones. [More]


Tiaano Waste Water Treatment by Electrolytic Method

clock July 8, 2020 18:56 by author admin
Mixing intensity and residence time determine whether the stated goals will be met. To determine mixing intensity define as the average shear intensity (mean velocity gradient) in the rapid-mix tank. The Camp-Stein equation is often used to compute this , however it is an equation which is based on laminar flow -- a case seldom found in rapid-mix or flocculation basins so it’s an “average” approximation. [More]


ELECTROLYTIC EFFLUENT TREATMENT PLANT (e-ETP)

clock July 6, 2020 20:38 by author admin
Traditional wastewater treatments involve the addition of chemicals or the use of microorganisms to treat polluted water. However, in both processes, there is always a residue known as sludge. The sludge management and final disposal could represent up to 50% of the total wastewater treatment plant cost. Therefore, novel ways to deal with this issue should be developed. In this way, the use of advanced oxidation processes (AOPs), in which the HO• radical production is favored, could represent an interesting option for treat wastewater with less or without sludge production. [More]


ELECTROLYTIC PRELIMINARY TEST/ APPRAISAL TEST KIT

clock July 3, 2020 14:41 by author admin
Electrocoagulation-flotation is an alternative method to classic chemical coagulation for many reasons. ECF is capable of reducing the need for chemicals due to the fact that the electrodes provide the coagulant. However, many individuals still use chemical coagulants to attempt to enhance treatment. Traditionally, chemical coagulation involves the use of alum (aluminum sulfate), ferric chloride (FeCl3), or ferrous sulfate (Fe2SO4) which can be very expensive depending on the volume of water treated. When applying the coagulant, the coagulant performs a similar function as the electrodes, neutralizing the charge of the particulates, thereby allow them to agglomerate and settle at the bottom of the tank. In addition, electrocoagulation-flotation is capable of reducing waste production from wastewater treatment and also reduces the time necessary for treatment. [More]


EFFLUENT TREATMENT PLANT & SEWAGE TREATMENT PLANT

clock July 2, 2020 18:25 by author admin
Electro-coagulation process removes ions, FOG, Silica, Organic particulate matter and helps in reduction of COD, BOD and suspended solids. Electro Coagulation Reactor treating of both black water (sewage) and grey water (domestic wastewater). [More]


EFFLUENT TREATMENT PLANT & SEWAGE TREATMENT PLANT

clock June 30, 2020 20:46 by author admin
Electrocoagulation-electroflotation (ECF) technology is a treatment process of applying electrical current to treat and flocculate contaminants without having to add coagulations. Shammas et al. stated that coagulation occurs with the current being applied, capable of removing small particles since direct current applied, setting them into motion. Also electrocoagulation could reduce residue for waste production. [More]